5915-01-235-6229 FILTER,BAND PASS Index 5970-01-235-6231 INSULATOR,ELECTRICAL,COOLING

National Stock Number:
5915-01-235-6230

Federal Supply Class:
5915

National Item Identification Number:
012356230

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1577P-313030LOCKHEED MARTIN SIPPICAN, INC.
EMIF0606-194117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
BODY HEIGHT1.330 INCHES NOMINAL
BODY LENGTH2.560 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH2.560 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.188 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.188 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH3.320 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.26 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION1.26 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 1ST RADIO INTERFERENCE 1ST FUNCTION2.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION126.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION126.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SPECIAL FEATURESTWO FILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0