National Stock Number: 6630-01-234-6794
Federal Supply Class: 6630
National Item Identification Number: 012346794
Description: ANALYZER,CLINICAL CHEMISTRY
Detail: A MICROPROCESSOR BASED INSTRUMENT INCORPORATING MORE THAN ONE METHOD OF ANALYSIS SUCH AS COLORIMETRIC AND POTENTIOMETRIC/ION SELECTIVE OR KINETIC ENZYME. IT MAY BE EITHER A STAND-ALONE UNIT OR MODULAR IN DESIGN. FOR INSTRUMENTS WHICH HAVE ONLY ONE METHOD OF ANALYSIS SEE ANALYZER, AS MODIFIED. EXCLUDES ALL INSTRUMENTS WHICH EMPLOY A CHROMATOGRAPHIC METHOD OF ANALYSIS.
|
Manufacturer Information:
1397399 | 88739 | FAIRBANKS INC FAIRBANKS SCALE DIV | 428605 | 22790 | BECTON, DICKINSON AND COMPANY | 4465 | 12717 | BECTON DICKINSON AND CO PRIMARY CARE DIAGNOSTICS DIV | 4466 | 12717 | BECTON DICKINSON AND CO PRIMARY CARE DIAGNOSTICS DIV | 4451 QBCII | 22790 | BECTON, DICKINSON AND COMPANY | 428605 | 4AZY5 | QBC DIAGNOSTICS LLC | 6-0148P | 64616 | DEFENSE MEDICAL STANDARDIZATION BOARD | 6630NCM162618 | 64616 | DEFENSE MEDICAL STANDARDIZATION BOARD | 6630-0284-0000 | 99998 | DEFENSE SUPPLY CENTER RICHMOND INDUSTRIAL PLANT EQUIPMENT /DLA/ |
|
Techincal Specification:
ACCESSORY COMPONENTS AND QUANTITY | ELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1 | CURRENT TYPE | AC | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM | PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER, CLINICAL CHEMISTRY | SPECIAL FEATURES | MICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO | SUPPLEMENTARY FEATURES | CONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED | UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE | 17741 | VOLTAGE IN VOLTS | 120.0 AND 220.0 |
|
|