Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
CW-H0028-01533875RAYTHEON E-SYSTEMS INC
VE411525714VERMILLION INCORPORATED


Techincal Specification:
COLORBLACK 1ST POSITION JACKET CABLE
CONDUCTOR QUANTITY7
CONDUCTOR SEQUENCE WITHIN GROUPSFIRST CONDUCTOR AND SECOND CONDUCTOR AND THIRD CONDUCTOR FIRST GROUP
CONDUCTOR SEQUENCE WITHIN GROUPSFOURTH CONDUCTOR AND FIFTH CONDUCTOR SECOND GROUP
CONDUCTOR SEQUENCE WITHIN GROUPSSIXTH CONDUCTOR AND SEVENTH CONDUCTOR THIRD GROUP
CONDUCTOR ARRANGEMENT AND QUANTITY1 TRIPLES AND 2 TWISTED PAIR
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE16 AWG ALL CONDUCTORS
SPECIAL FEATURESOUTER JACKET IS OF BRAIDED CONSTRUCTION
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR29 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING-55.0 CELSIUS AND 125.0 CELSIUS