5955-01-242-6194 OSCILLATOR,CRYSTALCONTROLLED Index 5962-01-242-6200 MICROCIRCUIT,DIGITAL

National Stock Number:
6130-01-242-6195

Federal Supply Class:
6130

National Item Identification Number:
012426195

Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
HB200-0.1254407POWER-ONE DC POWER SUPPLIES


Techincal Specification:
INPUT VOLTAGE RATING115.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT
230.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT
OVERALL LENGTH4.870 INCHES NOMINAL
OUTPUT VOLTAGE RATING175.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
210.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
OUTPUT CURRENT RATING0.1 DC AMPERES NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
FREQUENCY REGULATION PERCENT0.1 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICSLIMITING CURRENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
RIPPLE VOLTAGE AT FULL LOAD0.1 VOLTS PEAK MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT CONTROL TYPECURRENT LIMIT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
INPUT FREQUENCY RATING47.0 HERTZ NOMINAL 1ST OPERATING POWER RQMT
440.0 HERTZ NOMINAL 2ND OPERATING POWER RQMT
BATTERY QUANTITY1
BATTERY LOCATIONINTERNAL
ENVIRONMENTAL PROTECTIONSHOCK PROOF
OVERALL WIDTH4.000 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE0.1 TO 50.0 DEG CELSIUS