ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
III OUTPUT VOLTAGE RATING | 14.2 DC VOLTS MINIMUM AND 15.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
III OUTPUT VOLTAGE RATING | 27.0 DC VOLTS MINIMUM AND 29.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
III OUTPUT VOLTAGE RATING | 27.5 DC VOLTS MINIMUM AND 28.5 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
III OUTPUT VOLTAGE RATING | 4.8 DC VOLTS MINIMUM AND 5.5 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
PROPRIETARY CHARACTERISTICS | PACS |
OPERATING AMBIENT TEMP RANGE | +0.0 TO 70.0 DEG CELSIUS |
OUTPUT CURRENT RATING | 1.6 DC AMPERES MINIMUM AND 3.5 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
OUTPUT CURRENT RATING | 1.6 DC AMPERES MINIMUM AND 4.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
OUTPUT CURRENT RATING | 1.8 DC AMPERES MINIMUM AND 3.5 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
OUTPUT CURRENT RATING | 10.0 DC AMPERES MINIMUM AND 14.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
VENTILATION DESIGN TYPE | SINGLE FAN |