| FEATURES PROVIDED | INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION AND EMI FILTER AND OVER TEMPERATURE PROTECTION |
| FSC APPLICATION DATA | POWER SUPPLY ASSEMBLY 5865-01-187-5724 |
| INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
| INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
| INPUT VOLTAGE RATING | 230.0 DC VOLTS NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| INPUT VOLTAGE RATING | 400.0 DC VOLTS NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| OPERATING AMBIENT TEMP RANGE | -30.0 TO 170.0 FAHRENHEIT |
| OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL FIRST POWER OUTPUT |
| OUTPUT CURRENT RATING | -0.25 DC AMPERES NOMINAL FOURTH POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.25 DC AMPERES NOMINAL SECOND POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.25 DC AMPERES NOMINAL THIRD POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 14.0 DC VOLTS MINIMUM AND 16.0 DC VOLTS MAXIMUM SECOND POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 26.0 DC VOLTS MINIMUM AND 30.0 DC VOLTS MAXIMUM FIRST POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 3.0 DC VOLTS MINIMUM AND 7.0 DC VOLTS MAXIMUM THIRD POWER OUTPUT |
| OUTPUT VOLTAGE RATING | -14.0 DC VOLTS MINIMUM AND -16.0 DC VOLTS MAXIMUM FOURTH POWER OUTPUT |
| MAXIMUM OPERATING ALTITUDE RATING | 45000.0 FEET |
| NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
| POWER SUPPLY EFFICIENCY LINE | 90.0 |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | DIFFERENTIATED BY REPAIR PARTS |
| SPECIAL FEATURES | COOLING BY CONDUCTION TO A CHILL PLATE |
| WARM UP TIME IN MINUTES | 5 |