| SIGNAL DELAY METHOD | LUMPED CONSTANT |
| DELAY TIME VARIATION METHOD | TAPPED |
| INDIVIDUAL SECTION QUANTITY | 1 |
| SECTION DELAY TIME | 5.000 MICROSECONDS NOMINAL SINGLE SECTION |
| SEGMENT QUANTITY PER SECTION | 10 SINGLE SECTION |
| SEGMENT DELAY TIME | 3.000 MICROSECONDS NOMINAL SINGLE SECTION 1ST SEGMENT |
| 3.200 MICROSECONDS NOMINAL SINGLE SECTION 2ND SEGMENT |
| 3.400 MICROSECONDS NOMINAL SINGLE SECTION 3RD SEGMENT |
| 3.600 MICROSECONDS NOMINAL SINGLE SECTION 4TH SEGMENT |
| 3.800 MICROSECONDS NOMINAL SINGLE SECTION 5TH SEGMENT |
| 4.000 MICROSECONDS NOMINAL SINGLE SECTION 6TH SEGMENT |
| 4.200 MICROSECONDS NOMINAL SINGLE SECTION 7TH SEGMENT |
| 4.400 MICROSECONDS NOMINAL SINGLE SECTION 8TH SEGMENT |
| 4.600 MICROSECONDS NOMINAL SINGLE SECTION 9TH SEGMENT |
| 4.800 MICROSECONDS NOMINAL SINGLE SECTION 10TH SEGMENT |
| INPUT IMPEDANCE RATING | 500.000 OHMS |
| OUTPUT IMPEDANCE RATING | 500.000 OHMS |
| ATTENUATION IN DECIBELS | 3.000 |
| PULSE RISE TIME RATING | 143.0 MILLISECONDS |
| BODY STYLE | RECTANGULAR |
| BODY LENGTH | 3.980 INCHES MINIMUM AND |
| 4.020 INCHES MAXIMUM |
| BODY WIDTH | 2.980 INCHES MINIMUM AND |
| 3.020 INCHES MAXIMUM |
| BODY DEPTH | 0.480 INCHES MINIMUM AND |
| 0.520 INCHES MAXIMUM |
| MATERIAL AND LOCATION | STEEL, CORROSION RESISTING CASE AND |
| BRASS TERMINAL |
| SURFACE TREATMENT AND LOCATION | ENAMEL, MIL-E-15090 CASE AND |
| TINNED TERMINAL |
| TERMINAL TYPE AND QUANTITY | 14 WIRE LEADS |
| MOUNTING FACILITY | UNTHREADED HOLE |
| MOUNTING FACILITY QUANTITY | 4 |
| HOLE DIAMETER | 0.170 INCHES NOMINAL |
| MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.600 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.400 INCHES NOMINAL |