| SIGNAL DELAY METHOD | TRANSMISSION LINE |
| DELAY TIME VARIATION METHOD | TAPPED |
| INDIVIDUAL SECTION QUANTITY | 1 |
| SECTION DELAY TIME | 8.060 MICROSECONDS NOMINAL SINGLE SECTION |
| OPERATING TEMP RANGE | -54.0 TO 11.0 DEG CELSIUS |
| INPUT IMPEDANCE RATING | 560.000 OHMS |
| OUTPUT IMPEDANCE RATING | 560.000 OHMS |
| ATTENUATION IN DECIBELS | 2.000 |
| FREQUENCY BANDWIDTH | 580.0 KILOHERTZ NOMINAL |
| MATERIAL AND LOCATION | BRASS CASE |
| SURFACE TREATMENT AND LOCATION | PAINTED CASE |
| TERMINAL TYPE AND QUANTITY | 5 TAB SOLDER LUG |
| MOUNTING FACILITY | UNTHREADED HOLE |
| MOUNTING FACILITY QUANTITY | 4 |
| HOLE DIAMETER | 0.166 INCHES NOMINAL |
| MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 7.125 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.750 INCHES NOMINAL |
| FSC APPLICATION DATA | CODER,SYNCHRONIZER RADAR RECOGNITION SET |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 06481 |
| DESIGN CONTROL REFERENCE | 132018 |