| BEND ANGLE IN DEG | 90.0 FIRST BEND H-PLANE |
| BEND ANGLE IN DEG | 90.0 SECOND BEND H-PLANE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.440 INCHES NOMINAL ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.170 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 0.899 INCHES MINIMUM AND 0.901 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.620 INCHES NOMINAL ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.620 INCHES NOMINAL ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | RIGID ALL TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| SPECIAL FEATURES | DO NOT PAINT FLANGE FACES |
| STYLE DESIGNATOR | DOUBLE BEND TYPE |
| VOLTAGE STANDING WAVE RATIO | 1.05 |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 2.062 INCHES NOMINAL |
| WAVEGUIDE HEIGHT | 1.342 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.997 INCHES MINIMUM AND 1.003 INCHES MAXIMUM |
| SURFACE TREATMENT | CHROMATE AND PRIMER AND ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |