5910-00-919-8437 CAPACITOR,FIXED,PAPER DIELECTRIC Index 5970-00-919-8453 INSULATOR

National Stock Number:
5970-00-919-8452

Federal Supply Class:
5970

National Item Identification Number:
009198452

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
10041162-218876U S ARMY AVIATION AND MISSILE COMMAND
10041162A18876U S ARMY AVIATION AND MISSILE COMMAND
462A023-306090TE CONNECTIVITY CORPORATION
202-25204SP280378TRIUMPH AEROSTRUCTURES, LLC
304-1-B7K0720HELLERMANNTYTON LTD
304-1-B7K1793HELLERMANNTYTON LIMITED
462A023-3-006090TE CONNECTIVITY CORPORATION
6011ECCCP06090TE CONNECTIVITY CORPORATION
60IIECCCP06090TE CONNECTIVITY CORPORATION
C5075979-1857958SIGNALS WARFARE PROJECT MANAGER
SS7073-190178286SIKORSKY AIRCRAFT CORPORATION


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.690 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.980 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.520 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH3.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY


Click here to Register for Free 30-day Trial