| BODY HEIGHT | 2.718 INCHES MAXIMUM |
| BODY LENGTH | 2.218 INCHES MAXIMUM |
| BODY WIDTH | 2.015 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MAXIMUM TRANSFORMER POWER RATING | 89.8 VOLT-AMPERE SINGLE COMPONENT |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 29.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING CURRENT | 120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| WINDING OPERATING CURRENT | 120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING CURRENT | 120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL AND 16.00 AC VOLTS NOMINAL AND 21.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 780.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 168.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING VOLTAGE | 77.50 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING VOLTAGE | 77.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 77.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| SPECIFICATION/STANDARD DATA | 81349-MIL-T-27/129 GOVERNMENT SPECIFICATION |
| TERMINAL TYPE AND QUANTITY | 24 WIRE HOOK |
| TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |