5950-01-256-0101 COIL,ELECTRICAL Index 5950-01-256-0103 TRANSFORMER,POWER

National Stock Number:
5950-01-256-0102

Federal Supply Class:
5950

National Item Identification Number:
012560102

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
0-1173T109349MAGNETIC CIRCUIT ELEMENTS INC
180399603956NORTHROP GRUMMAN SYSTEMS CORPORATION
O-1173T109349MAGNETIC CIRCUIT ELEMENTS INC


Techincal Specification:
BODY WIDTH1.560 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRITICALITY CODE JUSTIFICATIONFEAT
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.060 INCHES MAXIMUM
OVERALL LENGTH3.360 INCHES MAXIMUM
MAXIMUM OPERATING TEMP85.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.166 INCHES MINIMUM AND 0.218 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
TERMINAL TYPE AND QUANTITY12 WIRE LEAD