5950-01-233-1237 TRANSFORMER,POWER Index 5910-01-233-1239 RETAINER,CAPACITOR

National Stock Number:
5950-01-233-1238

Federal Supply Class:
5950

National Item Identification Number:
012331238

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
8608W58P00397424AMETEK INC
AE3223TB19901ATLAS ENGINEERING CO INC PENTRONIC DIV
PEI854913483PRECISION ELECTRONICS, INC
K662451181KEYTRONICS, INC.
C1655772149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY LENGTH1.100 INCHES MAXIMUM
BODY OUTSIDE DIAMETER3.050 INCHES MAXIMUM
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING122.8 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY AND SIX SECONDARIES,FIFTH SECONDARY CENTER TAPPED AND SIXTH SECONDARY TAPPED W/O CENTER
WINDING OPERATING CURRENT1.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT210.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT360.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT720.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE28.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE30.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE239.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING OPERATING VOLTAGE9.60 AC VOLTS NOMINAL AND 28.00 AC VOLTS NOMINAL AND 37.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY23 WIRE LEAD
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial