5975-01-120-6083 CHASSIS,ELECTRICAL-ELECTRONIC EQ Index 5950-01-120-6085 COIL,RADIO FREQUENCY

National Stock Number:
5950-01-120-6084

Federal Supply Class:
5950

National Item Identification Number:
011206084

Description:
TRANSFORMER,CURRENT

Detail:
An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.


Manufacturer Information:
0377015634MAGNETIKA INC
10140325656DBP MICROWAVE INC. DBA
905828-106481NORTHROP GRUMMAN SYSTEMS CORPORATION
1305753854MAGNESPEC INC


Techincal Specification:
BODY HEIGHT0.550 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT0.950 INCHES NOMINAL
OVERALL LENGTH1.200 INCHES NOMINAL
OVERALL WIDTH1.200 INCHES NOMINAL
MAXIMUM OPERATING TEMP100.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT30.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT7.4 MILLIAMPERES AC MINIMUM AND 7.7 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY7 PIN