5950-00-172-9808 REACTOR Index 5950-00-172-9810 REACTOR

National Stock Number:
5950-00-172-9809

Federal Supply Class:
5950

National Item Identification Number:
001729809

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
73P821-00204660AIL SYSTEMS INC SUB OF EATON CORP
BX632185323BALTIMORE TRANSFORMER CO


Techincal Specification:
TERMINAL TYPE AND QUANTITY2 TURRET
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
WINDING OPERATING CURRENT6.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS0.100 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING400.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING400.0 HERTZ NOMINAL AND
2.4 KILOHERTZ MAXIMUM SINGLE COMPONENT
INDUCTANCE TYPEFIXED
MOUNTING METHODTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
OVERALL LENGTH1.820 INCHES NOMINAL
OVERALL HEIGHT1.120 INCHES NOMINAL
OVERALL WIDTH1.000 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONCORROSION RESISTANT


Click here to Register for Free 30-day Trial