5310-00-017-0524 WASHER,KEY Index 2925-00-017-0526 CAP,DISTRIBUTOR

National Stock Number:
5950-00-017-0525

Federal Supply Class:
5950

National Item Identification Number:
000170525

Description:
TRANSFORMER,AUDIO FREQUENCY

Detail:
A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.


Manufacturer Information:
5413056095750AIRCO REPUBLIC ELECTRONICS, INC.
MP15810-200213STRUTHERS-DUNN INC.
MP51810-21L8V1MAGNETIKA INC
MP51810-253342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
MP15810-253342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY6 TURRET
IMPEDANCE RATING IN OHMS10000.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY
160000.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
PRIMARY TO SECONDARY TURN RATIO1 TO 3 SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.980 INCHES MINIMUM AND
1.020 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.190 INCHES MINIMUM AND
0.230 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH1.400 INCHES MAXIMUM
BODY HEIGHT1.210 INCHES MAXIMUM
BODY WIDTH0.380 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TEST DATA DOCUMENT95750-54130560 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS