TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 96906-MS24568 GOVERNMENT STANDARD |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 18.630 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CASE MATERIAL | METAL |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-6106 |
MANUFACTURERS CODE | 96906 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MS24568-A2 |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 10.0 AMPERES DC RESISTIVE LOAD |
| 6.0 AMPERES AC AND |
| 10.0 AMPERES DC INDUCTIVE LOAD |
| 2.0 AMPERES AC AND |
| 3.0 AMPERES DC LAMP LOAD |
| 4.0 AMPERES AC AND |
| 6.0 AMPERES DC MOTOR LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |
TIME DELAY | 0.095 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.035 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 3.000 INCHES MAXIMUM |
OVERALL WIDTH | 2.700 INCHES MAXIMUM |
OVERALL HEIGHT | 2.300 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| 6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| RECTANGULAR SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 2.625 INCHES NOMINAL SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 1.250 INCHES NOMINAL SECOND MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.012 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 0.012 INCHES NOMINAL SECOND MOUNTING FACILITY |