| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 7.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC |
| OVERALL HEIGHT | 2.250 INCHES MAXIMUM |
| OVERALL LENGTH | 4.781 INCHES MAXIMUM |
| OVERALL WIDTH | 3.312 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING QUANTITY | 1 |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| TIME DELAY | 10.00 MINUTES NOMINAL FIXED OPERATE TIME |
| TIME DELAY | 10.00 MINUTES NOMINAL FIXED RELEASE TIME |