| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 4C |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC RESISTIVE LOAD |
| COIL QUANTITY | 2 |
| WINDING QUANTITY | 2 |
| WINDING DC RESISTANCE RATING | 1.1 KILOHMS NOMINAL FIRST WINDING |
| 170.0 OHMS NOMINAL SECOND WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 200.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES AC FIRST WINDING |
| 80.0 MILLIAMPERES AC SECOND WINDING |
| FREQUENCY IN HERTZ | 50.0 MINIMUM AND |
| 60.0 MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 16 PIN ALL FUNCTIONS |
| DUTY TYPE | INTERMITTENT |
| OVERALL LENGTH | 3.812 INCHES NOMINAL |
| OVERALL WIDTH | 2.219 INCHES NOMINAL |
| OVERALL HEIGHT | 2.437 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | LATCHING CONTACTS AND |
| POLARIZED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 82679 |
| DESIGN CONTROL REFERENCE | AR119 |