| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC AND VIBRATION RESISTANT |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC |
| OVERALL HEIGHT | 1.625 INCHES MAXIMUM |
| OVERALL LENGTH | 1.313 INCHES NOMINAL |
| MATERIAL | PLATINUM CONTACT |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 3.5 MILLIAMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.099 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PRECIOUS MATERIAL AND LOCATION | CONTACTS PALLADIUM |
| PRECIOUS MATERIAL | PALLADIUM |
| THREAD QUANTITY PER INCH | 48 SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 10.0 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG ALL FUNCTIONS |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |