NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND |
| 30.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 650.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ENERGIZING ELEMENT POWER RATING | 900.0 MILLIWATTS |
TERMINAL TYPE AND QUANTITY | 14 TAB, SOLDER LUG ALL FUNCTIONS |
TIME DELAY | 0.013 SECONDS NOMINAL FIXED OPERATE TIME |
| 0.006 SECONDS NOMINAL FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
OVERALL LENGTH | 1.109 INCHES MAXIMUM |
OVERALL WIDTH | 0.859 INCHES MAXIMUM |
OVERALL HEIGHT | 2.053 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD FIRST MOUNTING FACILITY |
| 1 THREADED STUD SECOND MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC FIRST MOUNTING FACILITY |
| UNC SECOND MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.099 INCHES FIRST MOUNTING FACILITY |
| 0.138 INCHES SECOND MOUNTING FACILITY |
THREAD CLASS | 2A FIRST MOUNTING FACILITY |
| 2A SECOND MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 48 FIRST MOUNTING FACILITY |
| 32 SECOND MOUNTING FACILITY |
THREAD LENGTH | 0.312 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 0.375 INCHES NOMINAL SECOND MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND FIRST MOUNTING FACILITY |
| RIGHT-HAND SECOND MOUNTING FACILITY |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CONTACT MATERIAL | SILVER |
CASE MATERIAL | PLASTIC |
PRECIOUS MATERIAL | SILVER |
PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |