OVERALL LENGTH | 3.875 INCHES NOMINAL |
OVERALL DIAMETER | 4.062 INCHES NOMINAL |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND |
| ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | 0.20 TO 1.00 ACTUATION POINT INCHES OF WATER AND |
| 0.20 TO 1.00 DEACTUATION POINT INCHES OF WATER |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SERRATED NUT AND |
| EXTERNAL ACTUATION POINT SERRATED NUT |
CONTACT STIMULUS RATING | 0.45 ACTUATION POINT NOMINAL INCHES OF WATER AND |
| 0.65 DEACTUATION POINT NOMINAL INCHES OF WATER AND |
| 0.20 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
CONTACT VOLTAGE RATING IN VOLTS | 24.0 DC AT SEA LEVEL SINGLE VOLTAGE |
CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
MEDIA FOR WHICH DESIGNED | LIQUID |
PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
TERMINAL TYPE | SCREW |
MOUNTING METHOD | THREADED BUSHING |
THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |
| NPTF ALL PRESSURE CONNECTION |
NOMINAL THREAD SIZE | 0.125 INCHES SINGLE PRESSURE CONNECTION |
| 0.500 INCHES SINGLE THREADED BUSHING |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |