5925-01-229-8653 CIRCUIT BREAKER Index 5925-01-229-8655 CIRCUIT BREAKER

National Stock Number:
5925-01-229-8654

Federal Supply Class:
5925

National Item Identification Number:
012298654

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
CD2-A3A6-85-240-1-1174193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CD2-Z-406-174193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
WT-C0078-00133875RAYTHEON E-SYSTEMS INC
CD2A3A6U-P1-85A240AC1-P2-115AC-P74193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CD2A3A9UP185A240AC1274193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CD2-Z-406-1L3330HEINEMANN ELECTRIC CANADA LIMITEE


Techincal Specification:
POLE QUANTITY2
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE85.0 AMPERES AC ALL LOCATIONS
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
TERMINAL TYPE AND QUANTITY6 THREADED STUD
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FIRST LOCATION
115.0 AC SECOND LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY FIRST LOCATION
INSTANTANEOUS SECOND LOCATION
RESET METHODMANUAL
BODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE AND
4 SLOT
CASE MATERIALPLASTIC
UNPACKAGED UNIT WEIGHT1.188 POUNDS NOMINAL
TRIP RELEASE METHODMAGNETIC ALL LOCATIONS
FREQUENCY IN HERTZ50.0 OR
60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
RELAY TRIP SECOND LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT35.000 MINIMUM AT 200 PCT AND
100.000 MAXIMUM AT 200 PCT FIRST LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BODY LENGTH5.768 INCHES MINIMUM AND
5.832 INCHES MAXIMUM
BODY WIDTH2.038 INCHES MINIMUM AND
2.102 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.515 INCHES MINIMUM AND
3.579 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.016 INCHES MINIMUM AND
1.036 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.718 INCHES MINIMUM AND
2.782 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.016 INCHES MINIMUM AND
1.036 INCHES MAXIMUM
BOSS HEIGHT0.209 INCHES MINIMUM AND
0.229 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE3.172 INCHES MINIMUM AND
3.296 INCHES MAXIMUM
THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MOUNTING SLOT WIDTH0.164 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFLAME RESISTANT AND
MOISTURE RESISTANT
ARC QUENCHING METHODMAGNETIC BLOWOUT
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
FRAGILITY FACTORMODERATELY RUGGED