POLE QUANTITY | 2 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 7.500 AMPERES AC ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
RESET METHOD | MANUAL |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
UNPACKAGED UNIT WEIGHT | 1.800 OUNCES NOMINAL |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
FREQUENCY IN HERTZ | 50.0 OR |
| 60.0 ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BUSHING LENGTH | 0.625 INCHES MAXIMUM |
BODY LENGTH | 1.562 INCHES MAXIMUM |
BODY WIDTH | 1.281 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | UNEF |
NOMINAL THREAD SIZE | 0.375 INCHES |
THREAD QUANTITY PER INCH | 32 |
SPECIAL TEST FEATURES | COMPLIES WITH INTERSTATE ELECTRONICS CORPORATION TECH STANDARDS |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SPECIAL TEST FEATURES |
PART NAME ASSIGNED BY CONTROLLING AGENCY | MAGNETIC CIRCUIT BREAKER |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 81541 |
DESIGN CONTROL REFERENCE | AP12-1RC-61F-1752 |