5310-01-045-2118 WASHER,FLAT Index 5935-01-045-2120 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5925-01-045-2119

Federal Supply Class:
5925

National Item Identification Number:
010452119

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
7276-101-3/482647SENSATA TECHNOLOGIES, INC.


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWOAT POLE TWO
ARC QUENCHING METHODAIRAIR
BODY LENGTH2.000 INCHES MAXIMUM2.000 INCHES MAXIMUM
BODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH0.850 INCHES MAXIMUM0.850 INCHES MAXIMUM
BUSHING LENGTH0.250 INCHES NOMINAL0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.800 INCHES NOMINAL0.800 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.500 INCHES NOMINAL0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 ALL LOCATIONS400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANTFUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPENONTRIP FREENONTRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC AND 120.0 AC AND 28.0 DC ALL LOCATIONS28.0 DC ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE750.0 MILLIAMPERES AC AND 750.0 MILLIAMPERES AC AND 750.0 MILLIAMPERES DC ALL LOCATIONS750.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 AC AND 500.0 AC AND 2000.0 DC ALL LOCATIONS2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE2.765 INCHES MAXIMUM2.765 INCHES MAXIMUM
NOMINAL THREAD SIZE0.469 INCHES0.469 INCHES
POLE QUANTITY33
RESET METHODMANUALMANUAL
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNSUNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 4.000 MINIMUM AT 200 PCT AND 35.000 MAXIMUM AT 200 PCT ALL LOCATIONS35.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL ALL LOCATIONS25.0 CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS
TRIP RELEASE METHODTHERMAL ALL LOCATIONSTHERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS125.0 ALL LOCATIONS
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY6 TAB W/SCREW6 TAB W/SCREW