5925-01-031-5935 CIRCUIT BREAKER Index 5925-01-031-5938 CIRCUITBREAKER

National Stock Number:
5925-01-031-5937

Federal Supply Class:
5925

National Item Identification Number:
010315937

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
9565860619333MAGNETIC PERIPHERALS INC NORMANDALE OPNS SUB OF CONTROL DATA CORP
9565860659661SYNTEGRA / USA/ INC COMPUTER PARTS AND SUPPLIES ARH205


Techincal Specification:
ACTUATOR FUNCTIONRESETRESET
ACTUATOR POSITION DESIGNATIONAT POLE ONEAT POLE ONE
BODY LENGTH1.156 INCHES NOMINAL1.156 INCHES NOMINAL
BODY STYLESINGLE POLE TYPESINGLE POLE TYPE
BODY WIDTH0.563 INCHES NOMINAL0.563 INCHES NOMINAL
BUSHING LENGTH0.391 INCHES NOMINAL0.391 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.000 INCHES NOMINAL1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ60.0 SINGLE LOCATION60.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANTFUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC AND 240.0 AC AND 50.0 DC SINGLE LOCATION50.0 DC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON1 PUSH BUTTON
MATERIALPLASTIC CASEPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE7.0 AMPERES AC AND 7.0 AMPERES AC AND 7.0 AMPERES DC SINGLE LOCATION7.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS700.0 AC AND 700.0 AC AND 700.0 DC SINGLE LOCATION700.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE2.250 INCHES NOMINAL2.250 INCHES NOMINAL
NOMINAL THREAD SIZE0.375 INCHES0.375 INCHES
POLE QUANTITY11
RESET METHODMANUALMANUAL
SPECIAL HANDLING FEATUREMAGNETICMAGNETIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATIONTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION125.0 SINGLE LOCATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 SCREW2 SCREW
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNEFUNEF


Click here to Register for Free 30-day Trial