| ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE TWOAT POLE TWO |
| BODY LENGTH | 1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM |
| BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE |
| BODY WIDTH | 1.937 INCHES MAXIMUM1.937 INCHES MAXIMUM |
| BUSHING LENGTH | 0.365 INCHES MINIMUM AND 0.365 INCHES MINIMUM AND 0.390 INCHES MAXIMUM0.390 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.865 INCHES MINIMUM AND 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM0.885 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM0.656 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS400.0 ALL LOCATIONS |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED AND HERMETICALLY SEALED AND MOISTURE RESISTANTMOISTURE RESISTANT |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 230.0 AC ALL LOCATIONS230.0 AC ALL LOCATIONS |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE1 TOGGLE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS10.0 AMPERES AC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC ALL LOCATIONS300.0 AC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING1 THREADED BUSHING |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.000 INCHES NOMINAL2.000 INCHES NOMINAL |
| NOMINAL THREAD SIZE | 0.375 INCHES0.375 INCHES |
| POLE QUANTITY | 33 |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES SILVERCONTACT SURFACES SILVER |
| PRECIOUS MATERIAL | SILVERSILVER |
| RESET METHOD | MANUALMANUAL |
| SPECIAL HANDLING FEATURE | MAGNETICMAGNETIC |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT AND 1.000 MINIMUM AT 200 PCT AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS5.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONSMAGNETIC-HYDRAULIC ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 ALL LOCATIONS130.0 ALL LOCATIONS |
| UNPACKAGED UNIT WEIGHT | 4.500 OUNCES NOMINAL4.500 OUNCES NOMINAL |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK6 WIRE HOOK |
| THREAD QUANTITY PER INCH | 3232 |
| THREAD SERIES DESIGNATOR | UNEFUNEF |