5925-00-145-5506 CIRCUIT BREAKER Index 5950-00-145-5513 TRANSFORMER,POWER

National Stock Number:
5925-00-145-5512

Federal Supply Class:
5925

National Item Identification Number:
001455512

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
111-204-10177342TE CONNECTIVITY CORPORATION
111-204-10179405WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
13-0550-004030598COMPUNETICS INC
7-1393246-377342TE CONNECTIVITY CORPORATION
W23X1A1G-477342TE CONNECTIVITY CORPORATION
CB300479405WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC


Techincal Specification:
POLE QUANTITY1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE4.0 AMPERES AC AND
4.0 AMPERES DC SINGLE LOCATION
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
TERMINAL TYPE AND QUANTITY2 TAB W/SCREW
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC AND
50.0 DC SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
RESET METHODMANUAL
BODY STYLESINGLE POLE TYPE
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
CASE MATERIALPLASTIC
UNPACKAGED UNIT WEIGHT2.000 OUNCES NOMINAL
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
FREQUENCY IN HERTZ400.0 SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC AND
2500.0 DC SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT11.000 MINIMUM AT 200 PCT AND
42.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0 SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BUSHING LENGTH0.375 INCHES NOMINAL
BODY LENGTH1.375 INCHES NOMINAL
BODY WIDTH0.687 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.020 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.035 INCHES NOMINAL
THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.375 INCHES
THREAD QUANTITY PER INCH24
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHUMIDITY RESISTANT AND
SALT SPRAY PROOF AND
SHOCK RESISTANT AND
VIBRATION RESISTANT
ARC QUENCHING METHODAIR
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
FRAGILITY FACTORMODERATELY RUGGED


Click here to Register for Free 30-day Trial