4820-01-339-2121 VALVE,CHECK Index 5930-01-339-2123 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-339-2122

Federal Supply Class:
5915

National Item Identification Number:
013392122

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1A20133H0297942NORTHROP GRUMMAN SYSTEMS CORPORATION
1A20133H0397942NORTHROP GRUMMAN SYSTEMS CORPORATION
88258-213058SORA POWER INC.
88258-313058SORA POWER INC.
8B258-313058SORA POWER INC.
RF14352-313619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY LENGTH9.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH8.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH7.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FEATURES PROVIDEDMOUNTING BRACKET
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OVERALL HEIGHT5.110 INCHES NOMINAL
OVERALL LENGTH11.000 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE800.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY5 SLOT LOCATION NOT OTHERWISE SPECIFIED
MOUNTING SLOT WIDTH0.203 INCHES NOMINAL
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
SPECIAL FEATURESINCLUDES TWO CHANNEL MOUNTING BRACKETS TOP AND BOTTOM
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES