| BODY HEIGHT | 1.250 INCHES NOMINAL |
| BODY LENGTH | 2.500 INCHES NOMINAL |
| BODY WIDTH | 2.000 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.250 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.05 AND 0.1 AND 0.3 AND 1.0 AND 1000.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 20.0 AND 40.0 AND 60.0 AND 70.0 |
| INCLOSURE TYPE | ENCASED |
| INPUT TERMINAL IDENTIFICATION | C1A-A10-14S-7P-10-1B |
| INPUT TERMINAL MANUFACTURER CODE | 14632 |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OVERALL HEIGHT | 1.625 INCHES NOMINAL |
| OVERALL LENGTH | 2.810 INCHES NOMINAL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.112 INCHES |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |