5930-01-158-2255 SWITCH,THERMOSTATIC Index 6150-01-158-2258 CABLE AND CONDUIT ASSEMBLY,ELECT

National Stock Number:
5915-01-158-2257

Federal Supply Class:
5915

National Item Identification Number:
011582257

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
721798-2205869RAYTHEON COMPANY
FX1575-80-4PS157032DADEN-ANTHONY ASSOCIATES INC SUB OF TRAK MICROWAVE
FX5000-77356216TELEDYNE WIRELESS, LLC
SM1575-80-4MS/M56216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION0.1 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.375 INCHES NOMINAL
BODY LENGTH2.750 INCHES NOMINAL
BODY WIDTH0.375 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS65.0 MINIMUM BLANK AND 1.8 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.565 GIGAHERTZ BLANK AND 1.585 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-0.0 TO 90.0 CELSIUS
OVERALL HEIGHT0.875 INCHES NOMINAL
OVERALL LENGTH3.400 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.575 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.565 GIGAHERTZ BLANK AND 1.585 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.185 GIGAHERTZ BLANK AND 1.565 GIGAHERTZ BLANK AND 1.585 GIGAHERTZ BLANK AND 1.965 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES