5915-01-041-2963 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-041-2966 SWITCH,PRESSURE

National Stock Number:
5915-01-041-2964

Federal Supply Class:
5915

National Item Identification Number:
010412964

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
32-811539-107397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
32-811539-150140K&L MICROWAVE LLC
6L250-670-007397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
6L250-670-050140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.250 INCHES NOMINAL0.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 NOMINAL BLANK AND 70.0 NOMINAL BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.00 HERTZ BLANK AND 670.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.75 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 95.0 CELSIUS+0.0 TO 95.0 CELSIUS
OVERALL LENGTH3.250 INCHES NOMINAL3.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION335.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0+10.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.0 HERTZ BLANK AND 670.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND 670.00 MEGAHERTZ BLANK AND 1.005 GIGAHERTZ BLANK AND 1.34 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES