5815-00-943-0263 ENQUIRY RESPONSE Index 5935-00-943-0271 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5915-00-943-0266

Federal Supply Class:
5915

National Item Identification Number:
009430266

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
180096203956NORTHROP GRUMMAN SYSTEMS CORPORATION
180096291709FUGLE-MILLER LABORATORIES


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT0.750 INCHES NOMINAL
BODY LENGTH1.844 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.400 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.400 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION380.00 HERTZ BLANK AND 420.00 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD22.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY7 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION400.0 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION360.00 HERTZ BLANK AND 380.00 HERTZ BLANK AND 420.00 HERTZ BLANK AND 1.20 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE