OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 10.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 10.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT AND |
| 4 TURRET INPUT AND |
| 2 TURRET GROUND |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 575.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 575.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 575.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 140.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OVERALL LENGTH | 13.380 INCHES NOMINAL |
OVERALL HEIGHT | 4.250 INCHES NOMINAL |
BODY LENGTH | 8.500 INCHES NOMINAL |
BODY HEIGHT | 3.000 INCHES MAXIMUM |
BODY WIDTH | 6.000 INCHES NOMINAL |
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | 3.500 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 12.875 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 5.562 INCHES NOMINAL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |