5910-01-234-7853 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-234-7855 CAPACITOR,FIXED,METALLIZED,PAPER

National Stock Number:
5910-01-234-7854

Federal Supply Class:
5910

National Item Identification Number:
012347854

Description:
CAPACITOR,FIXED,METALLIZED,PAPER

Detail:
A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.


Manufacturer Information:
09007037Z3DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (DRAWINGS)
09007-007F50558ELECTRONIC CONCEPTS, INC.
CFR12RRB103FM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CFR12RRB103FP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-55514/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.090 INCHES NOMINAL
BODY LENGTH0.190 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.200 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION0.010 MICROFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.200 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.300
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP70000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP500000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TOLERANCE RANGE PER SECTION-1.00 TO 1.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial