5905-00-175-5446 RESISTOR,THERMAL Index 5905-00-175-5448 RESISTOR,THERMAL

National Stock Number:
5905-00-175-5447

Federal Supply Class:
5905

National Item Identification Number:
001755447

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
19MS715-21MY97AGILENT TECHNOLOGIES, INC.
19MS715-228480HEWLETT-PACKARD COMPANY
22789856232LOCKHEED MARTIN CORPORATION
D16839264959AMERICAN TELEPHONE AND TELEGRAPH CO
D16839270408AT AND T CORP
B85164898738HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
RTD421900FEDERAL DIV OF VICTOREEN INSTRUMENT CO INC
P320A6073760ITT AEROSPACE CONTROLS LLC


Techincal Specification:
ZERO POWER RESISTANCE725.000 OHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
INCLOSURE TYPEENCAPSULATED
RELIABILITY INDICATORNOT ESTABLISHED
STYLE DESIGNATORDISK ON SURFACE PLATE
TERMINAL TYPE AND QUANTITY1 WIRE LEAD
SURFACE TREATMENTSOLDER TERMINAL
AMBIENT TEMP AT FULL RATED POWER25.0 DEG CELSIUS
MAXIMUM OPERATING TEMP150.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS80.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS150.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS4.40
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
-30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
-10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
25.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP46.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
13.05 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
3.045 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
2.465 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
725.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT
239.25 OHMS 6TH RESISTANCE-TEMPERATURE POINT
116.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
58.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
25.375 OHMS 9TH RESISTANCE-TEMPERATURE POINT
13.05 OHMS 10TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-11.0 TO 11.0 1ST RESISTANCE-TEMPERATURE POINT
-9.0 TO 9.0 2ND RESISTANCE-TEMPERATURE POINT
-8.4 TO 8.4 3RD RESISTANCE-TEMPERATURE POINT
-7.0 TO 7.0 4TH RESISTANCE-TEMPERATURE POINT
-5.0 TO 5.0 5TH RESISTANCE-TEMPERATURE POINT
-7.0 TO 7.0 6TH RESISTANCE-TEMPERATURE POINT
-8.6 TO 8.6 7TH RESISTANCE-TEMPERATURE POINT
-8.9 TO 8.9 8TH RESISTANCE-TEMPERATURE POINT
-10.0 TO 10.0 9TH RESISTANCE-TEMPERATURE POINT
-12.1 TO 12.1 10TH RESISTANCE-TEMPERATURE POINT
OVERALL LENGTH1.250 INCHES NOMINAL
OVERALL HEIGHT0.313 INCHES NOMINAL
OVERALL WIDTH0.875 INCHES NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.1285 INCHES NOMINAL
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.0624 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.6874 INCHES NOMINAL
TERMINAL LENGTH3.750 INCHES MINIMUM
TERMINAL DIAMETER0.025 INCHES NOMINAL
REFERENCE TEMP IN DEG CELSIUS25.0
CUBIC MEASURE0.342 CUBIC INCHES


Click here to Register for Free 30-day Trial