ZERO POWER RESISTANCE | 1.000 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -20.0 TO 20.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | BEAD TYPE EVACUATED OR GAS FILLED ENVELOPE |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
MAXIMUM POWER DISSIPATION RATING | 75.00 MILLIWATTS |
AMBIENT TEMP AT FULL RATED POWER | 175.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 275.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 32.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.75 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 54.9 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 5.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 405.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 184.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 92.3 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 50.3 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
| -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
| -12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT |
| -14.0 TO 14.0 4TH RESISTANCE-TEMPERATURE POINT |
| -17.0 TO 17.0 5TH RESISTANCE-TEMPERATURE POINT |
| -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT |
BODY LENGTH | 0.500 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.080 INCHES NOMINAL |
TERMINAL LENGTH | 1.500 INCHES MINIMUM |
TERMINAL DIAMETER | 0.012 INCHES NOMINAL |
TEST DATA DOCUMENT | 81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |