5905-00-138-3419 RESISTOR,FIXED,WIRE WOUND Index 5905-00-138-3421 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5905-00-138-3420

Federal Supply Class:
5905

National Item Identification Number:
001383420

Description:
RESISTOR,FIXED,WIRE WOUND

Detail:
INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.


Manufacturer Information:
0811-06401LQK8KEYSIGHT TECHNOLOGIES, INC.
0811-064028480HEWLETT-PACKARD COMPANY
KP61-1003T19587KELVIN INDUSTRIES INC
114-1003T20940MICRO-OHM CORPORATION
700654294SHALLCROSS INC
5E4750/921-000673030HAMILTON SUNDSTRAND CORPORATION
KP61-104PORM0.01-1/8W19587KELVIN INDUSTRIES INC
SP70-100KOHMPORM0.01PCT54294SHALLCROSS INC
R1213-1003T58880MEGGITT (NEW HAMPSHIRE), INC
RBR56L10002TR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39005/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39005/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
WWA23X000B10002M91637VISHAY DALE ELECTRONICS, LLC


Techincal Specification:
ELECTRICAL RESISTANCE100.000 KILOHMS
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER145.0
BODY DIAMETER0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
BODY LENGTH0.312 INCHES MINIMUM AND 0.364 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS0.125 FREE AIR
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-0.010 TO 0.010
SPECIFICATION/STANDARD DATA81349-MIL-R-39005/5 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-10.0 TO 10.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-65.0 TO 145.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).