2610-00-528-8779 INACTIVE Index 9510-00-528-8781 BAR,METAL

National Stock Number:
4920-00-528-8780

Federal Supply Class:
4920

National Item Identification Number:
005288780

Description:
TEST STAND,HYDRAULIC SYSTEM COMP

Detail:
A CABINETLIKE ITEM USUALLY WITH A FRONT WORK AREA AND CONSISTING OF THE NECESSARY INSTRUMENTATION, INTEGRAL HYDRAULIC SYSTEM AND COMPONENT MOUNTING FACILITIES. DESIGNED TO PROVIDE THE HYDRAULIC PRESSURE FOR TESTING AND/OR CALIBRATING HYDRAULIC SYSTEM COMPONENTS, SUCH AS VALVES, ACTUATING CYLINDERS, PRESSURE REGULATORS, ACCUMULATORS, HOSE LINES, HAND AND/OR ENGINE DRIVEN PUMPS AND THE LIKE. MAY INCLUDE FACILITIES FOR FILLING AND CHECKING HYDRAULIC SYSTEMS FOR LEAKAGE AND PERFORMANCE. SEE ALSO PUMPING UNIT, HYDRAULIC.


Manufacturer Information:
HTS2/E98750SAN ANTONIO AIR LOGISTICS CENTER
HTS2/E98752WARNER ROBINS AIR LOGISTICS CENTER
MK3A80049DEPARTMENT OF THE AIR FORCE
MIL-S-2600081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILS26017A81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILT26017B81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
PD97-LDEE-08TYPEIV98750SAN ANTONIO AIR LOGISTICS CENTER
PD97-LDEE-08TYPEIV98752WARNER ROBINS AIR LOGISTICS CENTER


Techincal Specification:
INSTALLATION DESIGNPORTABLE
USAGE DESIGNAIRCRAFT HYDRAULIC SYSTEM
PRESSURE RATING2750.0 POUNDS PER SQUARE INCH NOMINAL AND
4600.0 POUNDS PER SQUARE INCH NOMINAL
HYDRAULIC FLUID FLOW RATE42.0 GALLONS PER MINUTE
ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURENOT INCLUDED
POWER SOURCEELECTRIC MOTOR
HORSEPOWER RATING60.0
CURRENT TYPEAC
VOLTAGE IN VOLTS220.0 AND
440.0
FREQUENCY IN HERTZ60.0
PHASETHREE
PRESSURE MANIFOLD SUBCIRCUITNOT INCLUDED
ACCUMULATORNOT INCLUDED
FILTERING SYSTEMINCLUDED
PRESSURE/SUCTION HOSEINCLUDED
SPECIAL FEATURESTWO INDEPENDENT SYSTEMS; TRAILER MOUNTED; 0.0-27.0 GPM AT PRESSURE UP TO 3000.0 PSIG WITH A COMBINED FLOW OF 0.0-54.0 GPM AT PRESSURES UP TO 5000.0PSIG; THERMAL RELIEF VALVE; HIGH TEMP SWITCH; LOW PRESSURE SWITCH; POPPET TYPE CHECK VALVE AND A LOW TEMP SWITCH
NONDEFINITIVE SPEC/STD DATAMK3A TYPE
FUNCTIONAL CLASSIFICATIONGG-5.3
FUNCTIONAL DESCRIPTIONPERFORMANCE AND OPERATING CHARACTERISTICS
REFERENCE DATA AND LITERATURET.O.33A2-2-22-11
FSC APPLICATION DATAF/F-16,F-5,FB-111,F-105,E-4,B-57,A7D,A-10,C-141,AND C-5 ACFT


Click here to Register for Free 30-day Trial