Description:
VALVE,SOLENOID

Detail:
A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.


Manufacturer Information:
0RB3S393781PARKER-HANNIFIN CORP
886-219047X00527SNYDERGENERAL CORP COMMERCIAL PRODUCTS GROUP
ORB3S381978PARKER-HANNIFIN CORPORATION
ORB3S393781PARKER-HANNIFIN CORP


Techincal Specification:
APERTURE DIAMETER0.250 INCHES NOMINAL
CONNECTION TYPEUNTHREADED INTERNAL TUBE ALL ENDS
CONNECTION STYLESOCKET (TUBE) ALL ENDS
FLOW CONTROL DEVICE NORMAL OPERATION POSITIONOPEN
FLOW CONTROL DEVICEDIAPHRAGM
FREQUENCY IN HERTZ60.0
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL1.0 POUNDS PER SQUARE INCH MINIMUM AND 250.0 POUNDS PER SQUARE INCH MAXIMUM
OPERATING PRESSURE425.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE AND GLASS FIBER FLOW CONTROL DEVICE
MAXIMUM OPERATING TEMP200.0 FAHRENHEIT SINGLE RESPONSE
MEDIA FOR WHICH DESIGNEDREFRIGERANT 12 FIRST RESPONSE
MEDIA FOR WHICH DESIGNEDWATER-OIL-GAS SECOND RESPONSE
MOUNTING POSITIONHORIZONTAL OR VERTICAL
NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED0.375 INCHES ALL ENDS
PHASETHREE
VALVE OPERATION METHODSOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE208.0 AC AND 220.0 AC
STYLE DESIGNATORSTRAIGHT THRU