| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| BOLT HOLE DIAMETER | 0.406 INCHES NOMINAL FIRST END |
| BOLT HOLE QUANTITY | 4 FIRST END |
| BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 1.030 INCHES NOMINAL FIRST END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 2.062 INCHES NOMINAL FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE LENGTH | 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM FIRST END |
| FLANGE STYLE | DOUBLE OVAL (SAE SPLIT TYPE FLANGE) FIRST END |
| FLANGE THICKNESS | 0.315 INCHES NOMINAL FIRST END |
| FLANGE WIDTH | 2.220 INCHES NOMINAL FIRST END |
| HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.000 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| ITEM STRUCTURAL COMPOSITION | MOLDED RUBBER, SYNTHETIC OUTER LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID STEEL WIRE THIRD LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID STEEL WIRE FIRST LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID STEEL WIRE FOURTH LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID STEEL WIRE SECOND LAYER |
| OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTSIDE DIAMETER | 1.560 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 29.000 INCHES NOMINAL OVERALL |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 11.000 INCHES |
| TEMP RATING | -40.0 FAHRENHEIT AND 212.0 FAHRENHEIT SINGLE RESPONSE |