| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | ELBOW SECOND END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 20000.0 POUNDS PER SQUARE INCH |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE SECOND END |
| CONNECTION STYLE | PLAIN SECOND END |
| CONNECTION STYLE | PLAIN FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 1.750 INCHES NOMINAL FIRST END |
| FLANGE OUTSIDE DIAMETER | 1.750 INCHES NOMINAL SECOND END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES FIRST END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| FLOW ANGLE | 45.0 DEGREES SECOND END |
| INSIDE DIAMETER | 1.000 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| ITEM STRUCTURAL COMPOSITION | MOLDED RUBBER, SYNTHETIC OUTER LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID CORROSION RESISTANT STEEL WIRE FIRST LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID CORROSION RESISTANT STEEL WIRE FOURTH LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID CORROSION RESISTANT STEEL WIRE SECOND LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY LAID CORROSION RESISTANT STEEL WIRE THIRD LAYER |
| OPERATING PRESSURE | 5000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTSIDE DIAMETER | 1.510 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 36.000 INCHES NOMINAL WORKING |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 14.000 INCHES |
| TEMP RATING | -40.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |