| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END FLANGE CONSTRUCTION | SPLIT FIRST END |
| BOLT HOLE DIAMETER | 0.328 INCHES NOMINAL FIRST END |
| BOLT HOLE QUANTITY | 4 SECOND END |
| BURST TEST PRESSURE | 1400.0 POUNDS PER SQUARE INCH |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 2.375 INCHES NOMINAL FIRST END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 2.375 INCHES NOMINAL FIRST END |
| CONNECTION STYLE | RAISED SWIVEL FIRST END |
| CONNECTION TYPE | RAISED FACE FLANGE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE LENGTH | 3.000 INCHES NOMINAL FIRST END |
| FLANGE THICKNESS | 0.359 INCHES NOMINAL FIRST END |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) FIRST END |
| FLANGE WIDTH | 3.000 INCHES NOMINAL FIRST END |
| HYDROSTATIC TEST PRESSURE | 700.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.812 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 2ND LAYER BRAIDED STEEL WIRE AND 1ST LAYER RUBBER IMPREGNATED FABRIC AND OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD |
| OUTER COVERING ENVIRONMENTAL PROTECTION | MILDEW RESISTANT |
| OUTSIDE DIAMETER | 2.000 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 32.000 INCHES NOMINAL WORKING |
| MINIMUM INSIDE BENDING RADIUS | 13.100 INCHES |
| OPERATING PRESSURE | 350.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| RAISED FACE DIAMETER | 2.750 INCHES NOMINAL FIRST END |
| RAISED FACE HEIGHT | 0.020 INCHES NOMINAL FIRST END |
| TEMP RATING | -65.0 FAHRENHEIT AND 200.0 FAHRENHEIT SINGLE RESPONSE |