2220-01-237-3718 RAILWAY CAR,HOPPER Index 5910-01-237-3720 CAPACITOR,FIXED,METALLIZED,PAPER

National Stock Number:
4520-01-237-3719

Federal Supply Class:
4520

National Item Identification Number:
012373719

Description:
HEATER,WATER,LIQUID FUEL

Detail:
AN ITEM DESIGNED FOR HEATING WATER BY A DIRECT-FIRED METHOD, USING A LIQUID FUEL BURNED IN A COMBUSTION CHAMBER INCLOSED WITHIN ITSELF. IT MAY BE CAPABLE OF USING MORE THAN ONE TYPE OF FUEL, SUCH AS GASOLINE, OIL, KEROSINE, OR JET FUEL. IT MAY BE INCORPORATED WITH A TANK AS AN INTEGRAL OR AS A SEPARATE UNIT FOR STORAGE OF THE WATER SO HEATED. FOR ITEMS THAT USE LIQUEFIED PETROLEUM GAS, SEE HEATER, WATER, GAS. EXCLUDES SIDEARM HEATERS.


Manufacturer Information:
6-1-9912 ALTERED81337W1D1 NATICK SOLDIER CENTER
MIL-H-4408681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DEPARTURE FROM CITED DOCUMENTAS MODIFIED BY ALTERED DRAWING
GENERAL CHARACTERISTICS ITEM DESCRIPTIONSKID MTD;PORTABLE;CAPACITY 9 GALLONS OF WATER PER MINUTE WITH A TEMPERATURE RISE OF 100 DEG F;OPERATES ON 3 PHASE;60 HERTZ;208 V ELECTRICAL POWER SOURCE;BURNER OPERATES ON DIESEL (PRIMARY FUEL) AND GASOLINE (SECONDARY FUEL);WATER LEVEL CONTROLS;OPERATING CONTROL OUTLET WATER TEMPERATURE IS MAINTAINED BETWEEN 175 AND 210 DEG F;LIMIT CONTROL OUTLET WATER TEMPERATURE IS MAINTAINED BETWEEN 180 AND 194 DEG F;FLAME SAFEGUARD OPERATES BETWEEN 125 DEG F AND MINUS 20 DEG F;52.000 IN. O/A LG;27.000 IN. O/A W;47.000 IN. O/A H